Error number 0x800a138f updating windows top jewish dating

After that, BITS service fails to start The executable program that this service is configured to run does not implement the service.netsvcs registry value in HKLM\Software\Microsoft\Windows NT\Current Version\Svchost registry key should contain the service names that can be run in that service host.Microsoft.com/Downloads This has not been qualified by your hardware vendor for installation on this copy of Datacenter Server.Please contact your hardware vendor for additional information on obtaining a that has been qualified for your system configuration. _TSM_Hidden Field_=Rad Script Manager1_TSM&compress=1&_TSM_Combined Scripts_=;; Ajax Control Toolkit, Version=4.5.7.1005, Culture=neutral, Public Key Token=28f01b0e84b6d53e:en-US:a410b875-5cb5-4d5e-9cf6-234163990602:ea597d4b:b25378d2 0x800a138f - Java Script runtime error: Unable to set property 'control' of undefined or null reference Apparently this is happening at other places within the application as well in the deployed version, causing some components (such as Rad Upload) not to function correctly.Have tried different revs of telerik controls (1015, 926, 917), and different levels (4.5, 4.51, 4.0). Working Code: For example, receive this error: Unhandled exception at line 571, column 7 in - Java Script runtime error: Unable to get property 'remove Child' of undefined or null reference on a page with a Rad Upload control...For ex, if the proxy server is set to this error will be seen.This error is also seen when credentials are supplied such that scheme is not NTLM/Negotiate, but username/password is NULL, since that is not valid (Winhttp Set Credentials fails with E_INVALIDARG.

Please check that: a) No network or copy errors occurred during the integration process b) The format of the destination directory is correct.

Also try disabling the compression as described in this article and verify if the error is still showing. Could you please modify it in a way that the issue is observed and send it back in a support ticket?

I am attaching a sample project where I tested the code provided in the first post. This would enable us to further investigate the issue and provide you with an appropriate solution.

BITS 1.5 puts the job into ERROR state with BG_E_INVALID_RESPONSE in the above 2 cases, because of error code mapping E_INVALIDARG is always mapped to (BG_E_INVALID_SERVER_RESPONSE) Due to a bug in BITS 1.5 OOB setup, after BITS 1.5 install, the BITS service is deleted, but the 1.5 install returns success code.

BITS 1.5 binaries are copied to the machine, but the service doesnt exist.

Leave a Reply